Home / Annual Fireplace Service
- Check clearance to combustibles
- Check vent for blockage or soot
- Check for carbon and soot build up on burners, logs, and glass
- Take out logs and clean
- Gasket on glass (DV)
- Gasket on pilot assembly (DV)
- Check for proper pilot flame
- Check main burner flame for proper operation
- Check and refresh ember materials
- Check air shutter setting (DV)
- Check Restrictor setting
- Check pressure relief doors (DV)
- Dust and clean firebox chamber
- Check thermopile/voltage production
- Check blower snap disk
- Clean blower
- Check rheostat operation
- Check remote control operation
- Check thermostat operation
- Do a systems voltage check on millivolt value
- Check for gas leaks
- Remove Clean & Replace Ceramic Glass